<Error>
<ErrorNumber>16014</ErrorNumber>
<ErrorFamily>Image</ErrorFamily>
<ErrorMessage>
IMAGE: Can't flatten stroke
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This message appears when the exposure head is unable to create a flat beam profile
with enough power at each pixel. There are two reasons why this can happen. The beam
flatness tolerance may be set too small, or the laser output may be too low.
</text></DescriptionText>
<DescriptionText><text>
First step is to check if the beam has enough output power to expose the media in use
at the site.  If it does, you can adjust the stroke calibration tolerances using
set &lt;media&gt; stol and set &lt;media&gt; ltol.  If it doesn't, you need to investigate increasing
head output.
</text></DescriptionText>
<DescriptionText><text>
For full details on how to diagnose and solve this problem, see the hrx service pages. The url
is listed below.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Click on Resume to give the Platesetter another attempt.  If this error is reported again, Cancel this image
and lower the exposure level if possible.  Call Creo Service as the Platesetter may need servicing.
</text></DescriptionText>
</OperatorAction>
<Cause>
Head output is too low
</Cause>
<Cause>
Beam flatness tolerance is set too small
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/media_cal_stol.xml</LinkAddress><LinkTitle>NVS: media stol</LinkTitle></Link>
<Link><LinkAddress>../nvs/media_cal_ltol.xml</LinkAddress><LinkTitle>NVS: media ltol</LinkTitle></Link>
<Link><LinkAddress>../commands/daom.xml</LinkAddress><LinkTitle>Command: daom</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:28 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/heads/Hrx/nav/troubles.htm</LinkAddress><LinkTitle>Other: HRX Troubleshooting tips</LinkTitle></Link>
</Links>
</Error>